ADF
SM 4-53 D0CA/D0C9/D0C8/D0CB
&
Adjustment
• Align the platen sheet with hook and loop fastener [C], with the rear left corner [B] on
the exposure glass as a reference.
3. Close the A DF.
4. Reopen the A DF.
5. Press the surface of the platen sheet gently to fix it on the ADF firmly.
Adjustment after ADF Unit Replacement
See "Adjustment after CIS Unit Replacement".
4.6.2 ADF REAR COVER
1. Open the ADF top cover [A] and remove the screw.
2. Lift the original tray [B].