Firmware Update (Auto Remote Firmware Update)
D0CA/D0C9/D0C8/D0CB 5-28 SM
No. Situations in which the machine is determined to be in use
23 While importing/exporting SP settings
24 The interval between changing settings that require a reboot and actually rebooting (A
reboot notification message pops up after changing the settings.)
25 While verifying the operation panel (smart panel)
Update Process
When the machine updates the firmware by Auto Remote Firmware Update (ARFU), a
message dialog box opens to indicate the start of update.
“Cancel” and “OK” buttons appear in the dialog box. Update can be manually started by
pressing “OK” or starts automatically if the button is not pressed for 30 seconds.
If “Cancel” is pressed, the machine will perform the same retry process as when the machine is
in use at the time of update.
If the firmware update and three retries fail, the SC of the defective module during update will be
displayed as the update error. If the following SC occurs, replacing the corresponding device
restores the machine. The SC will not be reported to the call center.
Device name SC number
Engine board SC845-01
Controller board (PCB24) SC845-02
Operation panel (normal panel)
*1
SC845-03
Operation panel (smart panel) SC845-04
FCU (PCB2) SC845-05
*1 Not available for this machine