Electrical Components
D0CA/D0C9/D0C8/D0CB 4-220 SM
3. Remove the SMB [A] from the old BiCU and attach it to the new BiCU.
Attaching the used SMB to the new BiCU allows users to use old data such as SP
settings.
Replacing the SMB on the BiCU
The following shows the procedure for replacing the SMB on the BiCU (PCB1) with a
new SMB.
1. Make sure that you have the SMC report (factory settings). This report comes with the
machine.
2. Output the SMC data (“ALL”) using SP5-990-001 printed, or saved to SD card with
SP5-992-001.
3. Turn OFF the main power switch (SW1).
4. Insert a blank SD card in the SD slot #2, and then turn ON the main power switch (SW1).
5. Use SP5-824-001 to upload the SMB data from the BiCU (PCB1)
6. Turn OFF the main power switch (SW1) and unplug the power cord.