Fusing
D0CA/D0C9/D0C8/D0CB 4-154 SM
There are two screw holes for each screw on the entrance guide plate. Use the
outer holes when tightening the entrance guide plate.
Different types of screws are used for [A] and [B]:
[A]: Shoulder screw
[B]: Double sems screw (a screw with a washer)
4.14.5 FUSING THERMOSTAT (TH6)
1. Remove the fusing upper cover. (Fusing Upper Cover)
2. Remove the fusing thermostat (TH6) [A]. ( × 2)
Never reuse an activated thermostat. Use a new thermostat for replacement.
4.14.6 FUSING THERMISTOR (NON-CONTACT SENSOR) (S10)
If the hook of the fusing thermistor (non-contact sensor) (S10) is broken, the fusing
thermistor (non-contact sensor) (S10) cannot be attached. Replace the entire fusing
unit in that case.
1. Remove the fusing upper cover. (Fusing Upper Cover)