Self-Diagnostic Mode
SM 6-3 D0CA/D0C9/D0C8/D0CB
Troubleshooting
6.1.3 SC AUTOMATIC REBOOT
When an ordinary SC (pattern D) is generated, automatically reboot is performed. Automatic
reboot or reboot by user operation can be set by SP5-875-001 (SC automatic reboot setting
out) (default value: 1 "OFF").
When a type D occurs, automatic reboot is done or the machine display asks the customer if it
can reboot. However, when the SC occurs twice in a short time, the machine sends a report to
the @Remote server without rebooting. This is because just rebooting may not be a good
solution if an SC occurs twice.
When an automatic reboot is performed, a confirmation screen is displayed after reboot. The
confirmation screen can be cancelled by pressing the [OK] key (display is not cancelled only
when the main power switch (SW1) is switched OFF to ON).
Status display on the current screen
Post-processing ...... Post-processing during printing, etc.
Automatic reboot .... After operation end
Post-processing
Until automatic reboot
Reset key (Reboot key)
Key to perform reboot
# Cancel key is not displayed.
Turn on spanner LED (same as when an SC is generated).
Timing of SC reboot
When @Remote is enabled, and when a NRS alarm*1 is not generated, the corresponding
SC is the object of an automatic reboot.
*1 NRS alarm: Issued when an ordinary SC (type D) is generated twice while the total
counter counts 10 times.
Time to automatic reboot
Reboot is performed 30 seconds after an engine reboot is possible, after the end of
post-processing during printing, etc.
At that time, a reboot is performed even if the MFP is operating. The engine does not start
process control when a reboot is possible.
Automatic reboot
See the flowchart below.