Bypass
SM 4-183 D0CA/D0C9/D0C8/D0CB
&
Adjustment
4.16.5 BYPASS FEED ROLLER
Before replacing the bypass feed roller, reset the PM counter.
1. Turn the power ON.
2. Reset the PM counter. (Refer to Replacement Procedure of the PM/Yield Parts)
3. Turn the power OFF.
Remove the duplex unit.(Duplex Unit)
1. Remove the bypass feed unit. (Bypass Feed Unit)
2. Remove the bracket [A]. ( × 1)
3. Remove the E-ring [A] and bearing [B] at the front of the bypass feed unit. ( × 1, bearing
× 1)
4. Remove the E-ring and the gear at the rear of the bypass feed unit. ( × 1, gear × 1)