Main Machine Installation: Installation Procedures
SM 2-25 D0CA/D0C9/D0C8/D0CB
• SP2-117-001 (M)
• SP2-117-003 (Y)
The Color Registration (Color Skew Adjustment) should be executed if one or more of the
above SP values is not within ±5.
No Color Skew Adjustment is required if all SP values are within ±5.
The adjustment procedure is as follows:
Remove the paper exit tray [A].
1. Close the front cover.
2. Adjust the skew of the laser unit as follows:
Turn the knob for any color with a value other than "0", until it reads "0".
• Turning the knob clockwise by 90 degrees changes the SP value by -1.
• Turning the knob counter-clockwise by 90 degrees changes the SP value by +1.
• A click is felt every 90 degree rotation.