Internal Finisher (IM C400SRF Only)
SM 4-99 D0CA/D0C9/D0C8/D0CB
&
Adjustment
4.8.14 PAPER EXIT SENSOR (S43)
1. Remove the internal finisher. (Removing the Internal Finisher)
2. Remove the paper exit upper cover [A].
3. Remove the cover [A] ( x 1).
4. Remove the guide plate [A] ( x 1).