Firmware Update (Auto Remote Firmware Update)
SM 5-29 D0CA/D0C9/D0C8/D0CB
System
Maintenance
Using the operation panel, the user can cancel the update (including update through the
retry process) being performed by Auto Remote Firmware Update (ARFU).
However, while the firmware of the operation panel is being updated, cancellation is not
possible because the keys are disabled.
(Since the update of the operation panel firmware is performed at the end, you cannot cancel
the update at this point.)
If the update is canceled, the machine will reboot when the firmware update of all modules
included in the following parts is complete.
1. Engine Board
2. FCU (PCB2)
3. Controller Board (PCB24)
4. Operation Panel
For example, if the first firmware update for the Controller Board (PCB24) is canceled, the
machine will reboot when the firmware update of all modules included in the Controller Board
(PCB24) is complete.
The firmware configuration contained in the package is listed in the accompanying SERES
release note.
If the update is canceled, it will be performed again 76 hours later. If there is a difference in
version between the package obtained at that time and the one already stored (in other words,
the one canceled), the old package will be discarded and the latest one will be received.