SP2-XXX (Drum) -1
D0CA/D0C9/D0C8/D0CB 3-66 SM Appendices
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
2-308-00
2
Paper Size Correction Threshold 2 ENG
*
[0 to 250 / 165
/ 1mm/step]
2-308-00
3
Paper Size Correction Threshold 3 ENG
*
[0 to 250 / 139
/ 1mm/step]
2-311-001 Non Image Area: Bias Image Transfer ENG
*
[0 to 2000 /
100 /
10%/step]
2-311-003 Non Image Area: Bias Paper Transfer ENG
*
[0 to 2100 /
500 /
10-V/step]
2-316-00
1
Power ON: Bias Image Transfer ENG
*
[0 to 2100 /
1400 /
10V/step]
2-326-00
1
Transfer Roller CL: Bias Neg. Bias: Befor and
After JOB
ENG
*
[0 to 2100 /
250 /
10-V/step]
2-326-00
2
Transfer Roller CL: Bias Pos. Bias Cor Coef:
Befor and After JOB
ENG
*
[10 to 995 /
100 /
10%/step]
2-326-00
3
Transfer Roller CL: Bias Neg. Bias: After
ProControl
ENG
*
[0 to 2100 /
1000 /
10-V/step]
2-326-00
4
Transfer Roller CL: Bias Pos. Bias Corr Coef:
After ProCon
ENG
*
[10 to 995 /
100 /
10%/step]
2-326-00
5
Transfer Roller CL: Bias Neg. Bias: Dirt
Prevention
ENG
*
[0 to 2100 /
500 /
10-V/step]
2-326-011 Transfer Roller CL: Envir Neg. Bias: Befor and
After JOB
ENG
*
[1 to 100 / 9 /
1/step]
2-326-01
3
Transfer Roller CL: Envir Neg. Bias: After
ProControl
ENG
*
[1 to 100 / 2 /
1/step]
2-326-01
5
Transfer Roller CL: Envir Neg. Bias: Dirt
Prevention
ENG
*
[1 to 100 / 9 /
1/step]
2-327-00
1
PTR Cleaning After ProCon ON/OFF ENG
*
[0 to 1 / 1 /
1/step]