SP2-XXX (Drum) -2
SM Appendices
3-127 D0CA/D0C9/D0C8/D0CB
Appendices
SP Mode Tables
SP No. Large Category Small Category ENG
or CTL
[Min to
Max/Init./Step]
2-901-003 Fus.
Reload:DrumIdleTimeOffset
Coverage: 10-20% ENG* [-60 to 300 / -26 /
1sec/step]
2-901-004 Fus.
Reload:DrumIdleTimeOffset
Coverage: 20-40% ENG* [-60 to 300 / -21 /
1sec/step]
2-901-005 Fus.
Reload:DrumIdleTimeOffset
Coverage: 40% over ENG* [-60 to 300 / -21 /
1sec/step]
2-905-003 Dev Rvs Time Bk ENG* [0 to 200 / 80 /
10msec/step]
2-905-004 Dev Rvs Time Color ENG* [0 to 200 / 80 /
10msec/step]
2-905-005 Dev Rvs Threshold ALL ENG* [0 to 400000 /
18430 /
10mm/step]
2-905-006 Dev Rvs Counter Bk ENG* [0 to 999999999 / 0
/ 1mm/step]
2-905-007 Dev Rvs Counter Color ENG* [0 to 999999999 / 0
/ 1mm/step]
2-905-010 Dev pre-drive : ON/OFF ON/OFF ENG* [0 to 1 / 0 / 1/step]
0: OFF
1: ON
2-905-020 Last Dev drive speed Last Dev drive
speed:Bk
ENG* [0 to 2 / 0 / 1/step]
2-905-021 Last Dev drive speed Last Dev drive
speed:Col
ENG* [0 to 2 / 0 / 1/step]
2-905-030 Dev pre-drive : ON/OFF nomal-middle ENG [0 to 3 / 0 / 1/step]
2-905-031 Dev pre-drive : ON/OFF middle-low ENG [0 to 3 / 0 / 1/step]
2-905-032 Dev pre-drive : ON/OFF nomal-low ENG [0 to 3 / 0 / 1/step]
2-905-033 Dev pre-drive Threshould2 Absolute Humidity
Threshold
ENG [0.0 to 1000.0 /
10.3 /
0.1g/m3/step]
2-905-040 Development pre-drive
Distance
nomal speed pre-drive
distance
ENG IM C300 series: [0
to 5800 / 300 /
1mm/step]
IM C400 series: [0
to 5800 / 600 /
1mm/step]
2-905-041 Development pre-drive low speed pre-drive ENG [0 to 5800 / 300 /