SP3-XXX (Process)
D0CA/D0C9/D0C8/D0CB 3-178 SM Appendices
SP No. Large Category Small Category ENG
or
CTL
[Min to
Max/Init./Step]
2 *
3-701-22
3
Manual New Unit Set Toner Sub Hopper:Y ENG
*
[0 to 1 / 0 / 1/step]
3-710-00
1
mu Concentration
Control: Set
Control Method: Selection ENG
*
[0 to 1 / 1 / 1/step]
0: Not Use
1: Use
3-800-00
1
Waste Toner Full
Detection
Condition ENG
*
[0 to 4 / 0 / 1/step]
3-800-00
2
Waste Toner Full
Detection
Print Page After Near Full ENG
*
[0 to 10000 / 0 /
1sheets/step]
3-800-00
3
Waste Toner Full
Detection
Volume Count 1 After Near
Full
ENG
*
[0.0 to 100000.0 / 0.0
/ 0.1/step]
3-800-00
5
Waste Toner Full
Detection
Volume Count 2 After Near
Full
ENG
*
[0.0 to 1000000.0 /
0.0 / 0.1/step]
3-800-00
7
Waste Toner Full
Detection
Volume Count After
Replacement
ENG
*
[0.0 to 1000000.0 /
0.0 / 0.1/step]
3-800-01
2
Waste Toner Full
Detection
Remaining days Threshold ENG
*
[0 to 255 / 15 /
1/step]
3-800-02
0
Waste Toner Full
Detection
Mechanical Full Detection
Date
ENG
*
[0 to 1 / 0 / 1/step]
3-810-00
1
Paper Interval Ext.:
Low Spd
Formula: Slope ENG
*
[0 to 100 / 10 /
1%/step]
3-810-00
2
Paper Interval Ext.:
Low Spd
Formula: Intercept ENG
*
[-2000 to 2000 / 0 /
1%/step]
3-810-00
3
Paper Interval Ext.:
Low Spd
Formula: Upper Limit ENG
*
[100 to 2000 / 100 /
1%/step]

Table of Contents