SC4xx: Image Processing
SM 6-33 D0CA/D0C9/D0C8/D0CB
Troubleshooting
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
BiCU malfunction (Signal error)
High-Voltage Power Supply (Transfer) failure
Load related causes:
Increased impedance in the paper transfer roller
Increased impedance in the ITB
Open-circuit
Transfer unit not installed firmly
This is a logging SC (No action required).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC497-00 C Imaging Temperature Sensor Error
The thermistor output of the temperature sensor is not within the prescribed
range (more than 0.5 V to less than 3.0 V).
Damaged or loose connector
Defective Imaging Temperature Sensor (TH5)
Cycle the main power OFF/ON to check if this SC occurs again.
If this SC reoccurs, do the following:
1. Reconnect all the related connectors, and cycle the main power OFF/ON
to check if the SC reoccurs.
2. Replace the Imaging Temperature Sensor (TH5), and cycle the main
power OFF/ON to check if the SC reoccurs.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC498-00 C Temperature/Humidity Sensor Error
The thermistor output of the temperature sensor is not within the
prescribed range (more than 3.0V to less than 0.5V.
The thermistor output of the humidity sensor is not within the prescribed
range (2.4V or more).
Damaged or loose connector
Defective Temperature/Humidity Sensor (S18)
Cycle the main power OFF/ON to check if this SC occurs again.
If this SC reoccurs, do the following:
1. Reconnect all the related connectors, and cycle the main power OFF/ON
to check if the SC reoccurs.
2. Replace the Temperature/Humidity Sensor (S18), and cycle the main
power OFF/ON to check if the SC reoccurs.