SC5xx: Paper Feed and Fusing
D0CA/D0C9/D0C8/D0CB 6-50 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC593-00 A Pressure Roller Thermistor (edge: front) (TH2) High Temperature
(Software Error)
Pressure Roller Thermistor (edge: front) (TH2) detects a temperature of 248
degrees C for consecutive 10 times when the fusing lamp is activated.
Shorted triac
Defective BiCU (PCB1)
1. Reconnect the connectors between the fusing unit, fusing drawer
connector, and BiCU (PCB1).
2. Replace the Pressure Roller Thermistor (edge: front) (TH2).
3. Replace the harnesses between the BiCU (PCB1) and Pressure Roller
Thermistor (edge: front) (TH2)
4. Replace the BiCU (PCB1).
5. Replace the fusing unit if all the above steps cannot resolve the issue.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC594-00 A Pressure Roller Thermistor (edge: front) (TH2) High Temperature
(Hardware Error)
Pressure Roller Thermistor (edge: front) (TH2) detects a temperature of 248
degrees C.
Shorted triac
Defective BiCU (PCB1)
Defective fusing control system
1. Reconnect the connectors between the fusing unit, fusing drawer
connector, and BiCU (PCB1).
2. Replace the Pressure Roller Thermistor (edge: front) (TH2).
3. Replace the harnesses between the BiCU (PCB1) and Pressure Roller
Thermistor (edge: front) (TH2).
4. Replace the BiCU (PCB1).
5. Replace the fusing unit if all the above steps cannot resolve the issue.