SC6xx: Communication
D0CA/D0C9/D0C8/D0CB 6-64 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC670-05 C Linkup Error
If failing to link up by the 4th lane, the specified communication channel (and
instead linking up by the 1st or 2nd lane) at the PCIe I/F connection between
the controller and BiCU (PCB01) when the machine starts or returns from the
energy saver mode.
-
This is a logging SC.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC672-00 C Controller Start Up Error
After the machine was powered ON, communication between the controller
and the operation panel was not established, or communication with controller
was interrupted after a normal startup.
Controller stalled
Board installed incorrectly
Controller Board (PCB24) defective
Operation panel connector loose, broken or defective
1. Turn the main switch OFF and ON.
2. Check the connection of USB cable between the operation panel and the