SC6xx: Communication
SM 6-71 D0CA/D0C9/D0C8/D0CB
Troubleshooting
No. Description Cause
682 01 -
04
Invalid device ID Noise, Incorrect connection,
Malfunction
06 -
09
Channel error Noise, Incorrect connection,
Malfunction
11 -
14
Device Error Noise, Incorrect connection
16 -
19
Communication error (interrupted) Noise, Incorrect connection
21 -
24
Communication timeout Noise, Incorrect connection,
Malfunction
26 -
29
Device stops (logically) Noise, Incorrect connection,
Malfunction
31 -
34
Full of buffer (request) Noise, Incorrect connection,
Malfunction
36 -
39
Verification error Noise, Incorrect connection
51 Verification error (during storing to
EEPROM)
Noise
52 Verification error (SRAM) Noise
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC687-00 D PER Not Received Error
Unable to receive the PER command of the I/F commands from the
controller.
Unable to prepare the image data with the controller.
Communication error
The software of controller is defective.
1. Turn the main switch OFF and ON.