Process Control Error Conditions
D0CA/D0C9/D0C8/D0CB 6-128 SM
No. Result Description Possible Causes/Action
(S27-S29).
2. Replace the BiCU
(PCB1).
ID sensors (S27-S29)
are dirty:
1. Clean the ID sensors
(S27-S29).
2. Retry the process
control.
54 ID sensor coefficient
(K5) maximum/
minimum error
When the K5 is more than the
value of SP3-362-003 or less than
the value of SP3-362-004, the error
54 is displayed.
ID sensor pattern density
is too high or low.
ID sensors (S27-S29) or
shutter are defective.
Same as 53
55 Gamma error:
Maximum
Gamma is out of range. 5.0 <
Gamma
ID sensor pattern density
is too high.
Hardware defective.
Same as 53
56 Gamma error:
Minimum
Gamma is out of range.
Gamma < 0.15
ID sensor pattern density
is too low.
Hardware defective.
1. Same as 53
2. Replace the toner supply
pump unit.
57 Vk error: Maximum Vk is out of range.
150 < Vk
ID sensor pattern density
is too low.
Hardware defective.
Same as 53
58 Vk error: Minimum Vk is out of range.
Vk < –150
ID sensor pattern density
is too high.
Background dirty
Hardware defective
Same as 53
59 Sampling data error
during gamma
correction
Not enough data can be sampled
during the gamma correction.
ID sensor pattern density
is too high or low.
Hardware defective
Same as 53
99 Unexpected error Process control fails.
Power Failure