Process Control Error Conditions
D0CA/D0C9/D0C8/D0CB 6-128 SM
No. Result Description Possible Causes/Action
(S27-S29).
2. Replace the BiCU
(PCB1).
• ID sensors (S27-S29)
are dirty:
1. Clean the ID sensors
(S27-S29).
2. Retry the process
control.
54 ID sensor coefficient
(K5) maximum/
minimum error
When the K5 is more than the
value of SP3-362-003 or less than
the value of SP3-362-004, the error
54 is displayed.
• ID sensor pattern density
is too high or low.
• ID sensors (S27-S29) or
shutter are defective.
Same as 53
55 Gamma error:
Maximum
Gamma is out of range. 5.0 <
Gamma
• ID sensor pattern density
is too high.
• Hardware defective.
Same as 53
56 Gamma error:
Minimum
Gamma is out of range.
Gamma < 0.15
• ID sensor pattern density
is too low.
• Hardware defective.
1. Same as 53
2. Replace the toner supply
pump unit.
57 Vk error: Maximum Vk is out of range.
150 < Vk
• ID sensor pattern density
is too low.
• Hardware defective.
Same as 53
58 Vk error: Minimum Vk is out of range.
Vk < –150
• ID sensor pattern density
is too high.
• Background dirty
• Hardware defective
Same as 53
59 Sampling data error
during gamma
correction
Not enough data can be sampled
during the gamma correction.
• ID sensor pattern density
is too high or low.
• Hardware defective
Same as 53
99 Unexpected error Process control fails.
• Power Failure