Troubleshooting for Other Problems
SM 6-159 D0CA/D0C9/D0C8/D0CB
Related SPs
SP No. SP Name Function Description
SP1-158-001 Abnormal Noise
Confirmation: Unit:
Execute
The fusing motor (M13)
rotates with the heating
control.
Fails if the fusing unit is
not installed or the cover
is open
SP1-158-002 Abnormal Noise
Confirmation: No Unit:
Execute
The fusing motor (M13)
rotates without the heating
control.
Fails if the fusing unit is
installed or the cover is
open
SP1-158-003 Abnormal Noise
Confirmation: Operation
Time
Rotates during this time.
Initial value: 20 sec.
-
SP1-158-004 Abnormal Noise
Confirmation: Operation
Line Speed
Line speed at the time of
rotation
IM C300 series
0: 89 mm/s
1: 178 mm/s
2: 178 mm/s
3: 178 mm/s
IM C400 series
0: 89 mm/s
1: 178 mm/s
2: 252 mm/s
3: 276 mm/s
SP1-158-005 Abnormal Noise
Confirmation: Heat
Center Target Te m p
Temperature setting for
SP1-153-001 (Unit:
Execute)
Do not change
SP1-158-007 Abnormal Noise
Confirmation: Press
Target Temp
Temperature setting for
SP1-153-001 (Unit:
Execute)