Waveform generator (option R&S MXO4-B6)MXO 4 Series
437User Manual 1335.5337.02 ─ 07
Remote command:
WGENerator<wg>:VOLTage[:VPP] on page 862
Offset
Sets the vertical offset of the generated waveform.
Remote command:
WGENerator<wg>:VOLTage:OFFSet on page 861
Arbitrary Setup
Opens a menu to configure the arbitrary waveform.
See Chapter 15.1.4, "Arbitrary waveforms", on page 442.
Sweep
Opens a menu to configure the sweep.
See Chapter 15.1.3, "Sweep settings", on page 441.
Modulation
Opens a menu to configure the modulation.
See Chapter 15.1.2, "Modulation settings", on page 438.
Noise level in %
Sets the level of the noise in percentage of the set "Amplitude" output of the signal.
Remote command:
WGENerator<wg>:MODulation:NLPCent on page 868
User load
Select the user load, the load of the DUT at its connection.
You can select either a "50Ω" or a "High-Z" (high input impedance) load.
Remote command:
WGENerator<wg>:OUTPut[:LOAD] on page 859
Symmetry
Sets the symmetry of a ramp waveform, the percentage of time the waveform is rising.
By changing the symmetry of the ramp, you can create, for example, triangular wave-
forms.
50% defines symmetric triangles. Values <50% define triangles with steeper rising
edge leaned to the left. Values >50% define triangles with steeper falling edge leaned
to the right.
Remote command:
WGENerator<wg>:FUNCtion:RAMP[:SYMMetry] on page 858
Duty cycle
Sets the duty cycle for the pulse function.
The duty cycle expresses for what percentage of the period, the signal state is high.
Remote command:
WGENerator<wg>:FUNCtion[:SQUare]:DCYCle on page 859
Setup of the waveform generator