Protocol analysis
R&S
®
RTE
761User Manual 1326.1032.02 ─ 20
"Error Condition"
Searches for the end of certain error events.
Description of trigger type specific settings: "Error conditions setup"
on page 764
Remote command:
SEARch:TRIGger:SENT:CALibration on page 1719
SEARch:TRIGger:SENT:TRANsmission on page 1720
SEARch:TRIGger:SENT:SMSG on page 1720
SEARch:TRIGger:SENT:ERRor on page 1720
Transmission Sequence setup
Configures the search conditions for the transmission sequence.
Note: The displayed parameters depend on the selected "Sequence". The instrument
displays the data setting parameters when you select "Status+Data", see "Sequence"
on page 761.
The search type specific conditions are the same as for the trigger type, see "Trans-
mission Sequence setup" on page 740.
Figure 13-69: Search setting parameters of a transmission sequence
Sequence ← Transmission Sequence setup
Selects the condition for searching in a single transmission sequence.
You can search for the end of the status nibble or the combination of the status and
data nibble(s).
Remote command:
SEARch:TRIGger:SENT:TTYPe on page 1721
Status ← Transmission Sequence setup
Defines the data bits for the status nibble.
Remote command:
SEARch:TRIGger:SENT:STATus on page 1721
SENT (option R&S
RTE-K10)