Compliance tests
R&S
®
RTP
1081User Manual 1337.9952.02 ─ 12
R&S®RT-ZF6 Frequency Converter Manual
20.2.1 Test equipment
For Ethernet compliance tests, the following test equipment is needed:
The free-of-charge R&S ScopeSuite software, which can be installed on a com-
puter or directly on the oscilloscope.
10/100/1000BASE-T Ethernet compliance tests:
R&S RTO/R&S RTP oscilloscope with at least 600 MHz bandwidth
Differential probe with at least 1 GHz bandwidth
R&S RTO/R&S RTP-K22 10/100/1000BASE-T Ethernet compliance test option
(required option, installed on the oscilloscope)
R&S RT-ZF2 Ethernet test fixture set
For energy-efficient Ethernet tests, in addition:
R&S RT-ZF5 Ethernet test fixture set for 100/1000BASE-T EEE tests
R&S RT-ZF4 test fixture for 10BASE-Te tests
2.5GBASE-T Ethernet compliance tests:
R&S RTO/R&S RTP oscilloscope with at least 600 MHz bandwidth
For precise power spectral density and power level measurements up to
1 GHz, it is recommended to use an oscilloscope and a differential probe with
1 GHz bandwidth each.
Differential probe with at least 1GHz bandwidth
R&S RTO/R&S RTP-K23 GBASE-T Ethernet compliance test option (required
option, installed on the R&S RTP)
R&S RT-ZF2 Ethernet test fixture set
5GBASE-T Ethernet compliance tests:
R&S RTO/R&S RTP oscilloscope with at least 1 GHz bandwidth
For precise power spectral density and power level measurements up to
1.5 GHz, it is recommended to use an oscilloscope and a differential probe with
1.5 GHz bandwidth each.
Differential probe with at least 1.5 GHz bandwidth
R&S RTO/R&S RTP-K23 GBASE-T Ethernet compliance test option (required
option, installed on the R&S RTP)
R&S RT-ZF2 Ethernet test fixture set
10GBASE-T Ethernet compliance tests:
R&S RTO/R&S RTP oscilloscope with at least 2 GHz bandwidth
For precise power spectral density and power level measurements up to
3 GHz, it is recommended to use an oscilloscope and a differential probe with
3 GHz bandwidth each.
Differential probe with at least 3 GHz bandwidth
R&S RTO/R&S RTP-K23 GBASE-T Ethernet compliance test option (required
option, installed on the R&S RTP)
R&S RT-ZF2 Ethernet test fixture set
Ethernet compliance tests (options R&S
RTP-K22/K23/K25/K86)

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Related product manuals