Remote control commands
R&S
®
RTP
1727User Manual 1337.9952.02 ─ 12
Return values:
<FrameStart> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
22.17.10 Ethernet 10BASE-T and 100BASE-TX (option R&S RTP-K8)
Configuration.......................................................................................................1727
Trigger.................................................................................................................1730
Decode results.................................................................................................... 1735
Search settings................................................................................................... 1740
Search results..................................................................................................... 1746
22.17.10.1 Configuration
In all BUS<m>:ETHernet commands, the suffix <m> selects the serial bus.
BUS<m>:ETHernet:VARiant..........................................................................................1727
BUS<m>:ETHernet:SOURce.........................................................................................1727
BUS<m>:ETHernet:POLarity.........................................................................................1728
BUS<m>:ETHernet:THReshold:HIGH............................................................................ 1728
BUS<m>:ETHernet:THReshold:LOW.............................................................................1728
BUS<m>:ETHernet:PRESet..........................................................................................1729
BUS<m>:ETHernet:BITRate..........................................................................................1729
BUS<m>:ETHernet:VARiant <Variant>
Selects the Ethernet protocol variant and transmission speed.
Suffix:
<m>
.
1..4
Parameters:
<Variant> B10T | B100TX | B100tx
B10T
Ethernet protocol variant 10BASE-T (10 Mbit/s)
B100TX = B100tx
Ethernet protocol variant 100BASE-TX (100 Mbit/s)
*RST: B10T
BUS<m>:ETHernet:SOURce <SourceData>
Selects the source channel for the data signal.
Usually, the source is one of the analog channels. Reference and math waveforms are
available as source if the trigger source is one of the analog channels but not the serial
bus.