Compliance tests
R&S
®
RTP
1083User Manual 1337.9952.02 ─ 12
20.3.1 Test equipment
For D-PHY compliance tests, the following test equipment is needed:
●
R&S RTP oscilloscope with 4 channels and at least 4 GHz bandwidth
●
For measuring the clock signal (+ and -): either 1 differential probe or 2 single-
ended probes with at least 4 GHz bandwidth. However, note that D-PHY Group 2
and Group 4 tests require 2 probes for the clock signal.
●
For measuring the data signal (+ and -): 2 probes with at least 4 GHz bandwidth
●
R&S RTP-K26 D-PHY compliance test option (required option, installed on the
oscilloscope)
●
Recommended test fixture for LP-TX tests: MIPI D-PHY Capacitive Load (C
LOAD
)
fixture from The University of New Hampshire InterOperability Laboratory (UNH-
IOL)
●
Recommended termination board for HS-TX tests: MIPI D-PHY Reference Termi-
nation Board (RTB) from The University of New Hampshire InterOperability Labora-
tory (UNH-IOL)
●
The free-of-charge R&S ScopeSuite software, which can be installed on a com-
puter or directly on the oscilloscope.
20.4 eMMC compliance tests (option R&S RTP-K92)
The option R&S RTP-K92 enables the automatic processing of eMMC compliance
tests.
The eMMC compliance test procedures are described in a separate manual:
●
eMMC Compliance Tests, Test Procedures Manual"
20.4.1 Test equipment
For eMMC compliance tests, the following test equipment is needed:
●
R&S RTP oscilloscope with at least 1 GHz bandwidth
●
A probe with at least 1.5 GHz bandwidth
●
R&S RTP-K92 eMMC compliance test option (required option, installed on the
R&S RTP)
●
The free-of-charge R&S ScopeSuite software, which can be installed on a com-
puter or directly on the R&S RTP.
20.5 PCIe compliance tests (option R&S RTP-K81)
The option R&S RTP-K81 enables the automatic processing of PCIe 1.1 / PCIe 2.0
compliance tests.
PCIe compliance tests (option R&S