Getting started
R&S
®
RTP
52User Manual 1337.9952.02 ─ 12
Ref In, Ref Out
BNC connectors for input of a reference signal, and for output of the OCXO reference
signal.
The input frequency ranges from 1 MHz to 20 MHz in 1 MHz steps. The input impe-
dance is 50 Ω.
The output frequency of the OCXO is 10 MHz, the impedance is 50 Ω. For detailed
specifications, refer to the data sheet.
DDI 40G
Optional digital data interface for input and output of digital data.
Option slot
Slot to install one of the options R&S RTP-B1 (MSO) or R&S RTP-B1E (for R&S RT-
ZVC) if both slots at the front panel are used for other options. To install the option, the
R&S RTP-B21 slot adapter is required. The options and their connectors are briefly
described in Chapter 3.2.1, "Front panel", on page 47.
3.2.3 Keys and controls
3.2.3.1 Power key
The [Power] key is located on the lower left corner of the front panel. It starts up and
shuts down the instrument's software.
The light of the key shows the instrument state:
Standby, the main power switch is on, the software is shut down: orange.
The instrument is ready for operation: green.
See also: Chapter 3.1.7, "Switching on or off", on page 44.
3.2.3.2 Setup controls
Setup keys set the instrument to a defined state, change basic settings, and provide
saving and help functions. The intensity rotary knob adjusts the display contrast for
several display elements.
[Autoset]
The instrument analyzes the enabled channel signals, and adjusts appropriate horizon-
tal, vertical, and trigger settings to display stable waveforms.
[Preset]
Resets the instrument to a default state. All measurements, mask tests, zoom, and
most individual settings are deleted, and all channels except for channel 1 are dis-
abled. You can define preset configurations and save them to a file. The [Preset] key
can be configured to set either factory defaults or a user-defined preset configuration.
Instrument tour