Remote control commands
R&S
®
RTP
1261User Manual 1337.9952.02 ─ 12
LONGer
Triggers on pulses longer than the given width.
*RST: WITHin
Usage: Asynchronous command
TRIGger<m>:WIDTh:WIDTh <Width>
For the ranges "Within" and "Outside" (defined using TRIGger<m>:WIDTh:RANGe),
the width defines the center of a range which is defined by the limits "±Delta" (see
TRIGger<m>:WIDTh:DELTa on page 1261).
For the ranges "Shorter" and "Longer", the width defines the maximum and minimum
pulse width, respectively.
Suffix:
<m>
.
1..3
1 = A-trigger, 2 = B-trigger, 3 = R-trigger
Parameters:
<Width> Range: 100E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:WIDTh:DELTa <WidthDelta>
Defines a range around the width value specified using TRIGger<m>:WIDTh:WIDTh.
Suffix:
<m>
.
1..3
1 = A-trigger, 2 = B-trigger, 3 = R-trigger
Parameters:
<WidthDelta> Range: 0 to 432
Increment: 500E-12
*RST: 0
Default unit: s
Usage: Asynchronous command
22.9.5 Runt trigger
TRIGger<m>:RUNT:POLarity........................................................................................ 1262
TRIGger<m>:LEVel<n>:RUNT:LOWer............................................................................1262
TRIGger<m>:LEVel<n>:RUNT:UPPer............................................................................ 1262
TRIGger<m>:RUNT:RANGe..........................................................................................1262
TRIGger<m>:RUNT:WIDTh...........................................................................................1263
TRIGger<m>:RUNT:DELTa........................................................................................... 1263