EasyManua.ls Logo

Rohde & Schwarz RTP Series - Jitter Measurements; Protocol Measurements (Option R&S RTP-K35); Protocol Measurements (Option R&SRTP-K35)

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Measurements
R&S
®
RTP
381User Manual 1337.9952.02 ─ 12
Source
Selects the histogram on which the measurement is based. Before, you have to define
a histogram, see Chapter 8.2.8.3, "Creating histograms", on page 378.
Remote command:
MEASurement<m>:HISTogram:SELect on page 1405
Probability domain marker, Reference
Defines the marker reference in the probability domain.
"Peak"
The y-value with the maximum sample value in the histogram
"Upper Peak"
The y-value at the maximum sample value in the upper half of the
histogram
"Lower Peak"
The y-value at the maximum sample value in the lower half of the his-
togram
"Maximum"
The highest y-value with a probability > 0
"Minimum"
The lowest y-value with a probability > 0
"Median"
The y-value for which half the samples lie above, the other half below
in the histogram.
"Mean"
The weighted arithmetic average of the histogram
Remote command:
MEASurement<m>:HISTogram:PROBability:TYPE on page 1406
Probability domain marker, Delta
Defines a range around the marker.
Remote command:
MEASurement<m>:HISTogram:PROBability:LIMit on page 1406
8.2.9 Jitter measurements
Jitter measurements are availabe if one of the following options is installed:
R&S RTP-K12
R&S RTP-K133
R&S RTP-K134
See Chapter 18.1, "Jitter measurements (Option R&S RTP-K12)", on page 1013.
8.2.10 Protocol measurements (option R&S RTP-K35)
Option R&S RTP-K35 provides specific measurements on automotive and Ethernet
protocols.
Automatic measurements