Compliance tests
R&S
®
RTP
1082User Manual 1337.9952.02 ─ 12
●
100BASE-T1 compliance tests:
– R&S RTO/R&S RTP oscilloscope with at least 600 MHz bandwidth
– Differential probe with 1 GHz bandwidth
– R&S RTO/R&S RTP-K24 100BASE-T1 compliance test option (required option,
installed on the R&S RTP)
– R&S RT-ZF2 Ethernet test fixture set
– R&S RT-ZF3 frequency converter for transmitter distortion tests
●
1000BASE-T1 compliance tests:
– R&S RTO/R&S RTP oscilloscope with at least 2 GHz bandwidth
– Differential probe with 2 GHz bandwidth
– R&S RTO/R&S RTP-K87 1000BASE-T1 compliance test option (required
option, installed on the R&S RTP)
– R&S RT-ZF2 Ethernet test fixture set
– R&S RT-ZF6 frequency converter for transmitter distortion tests
●
MGBASE-T1 compliance tests:
– R&S RTO / R&S RTO6 /R&S RTP oscilloscope, with a bandwidth of:
- for 2.5 GBASE-T1 tests: at least 3.5 GHz
- for 5 GBASE-T1 tests: at least 7 GHz
- for 10 GBASE-T1 tests: at least 14 GHz
– 2 BNC/SMA cables
– R&S RTO/R&S RTP-K88 MGBASE-T1 compliance test option (required option,
installed on the R&S RTP)
●
10BASE-T1 compliance tests:
– R&S RTO/R&S RTP oscilloscope
– Optional Differential probe with 1 GHz bandwidth
– R&S RTO/R&S RTP-K89 10BASE-T1 compliance test option (required option,
installed on the R&S RTP)
●
R&S RTO-B6/R&S RTP-B6/Tabor WX2182B/Tabor WX2182C arbitrary waveform
generator for automatic disturber tests. For some disturber tests, also HMF2550
can be used.
●
R&S ZNB/ZNC/ZND/ZVL vector network analyzer for automatic return loss mea-
surements. For manual measurements, also other AWGs and VNAs can be used.
20.3 D-PHY compliance tests (option R&S RTP-K26)
The option R&S RTP-K26 enables the automatic processing of D-PHY compliance
tests.
The D-PHY compliance test procedures are described in a separate manual:
●
R&S®RTO-K26, R&S®RTP-K26, D-PHY Compliance Test, User Manual"
D-PHY compliance tests (option R&S
RTP-K26)