Deembedding (Option R&S RTP-K121/-K122)
R&S
®
RTP
1065User Manual 1337.9952.02 ─ 12
Enable
Enables the component for deembedding. As long as the configuration is incomplete or
conflicting, the message "Invalid configuration" is shown, and enabling is not possible.
Remote command:
DEEMbedding<m>:COMPonent<n>[:STATe] on page 2296
Component
Selects the component type. The "DUT", "Input" and "Probe" types are predefined and
shown for information. The other types ("Fixture", "Cable", "Adapter", and "Other") are
selectable.
Remote command:
DEEMbedding<m>:COMPonent<n>:TYPE on page 2297
Name
Enter a name for the component that helps you identifying it.
Remote command:
DEEMbedding<m>:COMPonent<n>:NAME on page 2297
Total ports
Shows the number of all ports of the selected component (input ports and output
ports).
The number of ports depends on the attached probe. If a modular probe R&S RT-ZM
or differential probe R&S RT-ZD is used, the number of ports is 4. Otherwise, 2 ports
are available.
Remote command:
DEEMbedding<m>:COMPonent<n>:PCOunt? on page 2297