EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1421

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1421User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page 1359.
Parameters:
<FrameName>
MEASurement<m>:PROTocol:SBITrate:VAL <SecondaryBtRateIdVal>
Sets the field value of the frame for the secondary bit rate protocol measurement.
Suffix:
<m>
.
1..10
See "Selection of the measurement group: MEASurement<m>"
on page 1359.
Parameters:
<SecondaryBtRateIdVal>
Usage: Asynchronous command
MEASurement<m>:PROTocol:T2FRame:DIRection <TrigFrmDirct>
Sets the direction of the field for trigger to frame protocol measurement.
Suffix:
<m>
.
1..10
Parameters:
<TrigFrmDirct> T2F | F2T
T2F: trigger to frame
F2T: frame to trigger
*RST: T2F
Usage: Asynchronous command
MEASurement<m>:PROTocol:T2FRame:FLD <FieldName>
Sets the type of the field for trigger to frame protocol measurement.
Suffix:
<m>
.
1..10
Parameters:
<FieldName>
MEASurement<m>:PROTocol:T2FRame:FRM <FrameName>
Sets the value of the frame for trigger to frame protocol measurement.
Automatic measurements