Remote control commands
R&S
®
RTP
1434User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Value>
Example:
REFLevel2:ABSolute:HIGH 0.015
Sets the high signal level for Ch1Wfm1 to 15 mV. C1W1 corre-
sponds to suffix number 2.
Usage: Asynchronous command
REFLevel<m>:ABSolute:LOW
<Value>
The signal value that represents a low level.
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Value>
Example:
REFLevel2:ABSolute:Low 0.0015
Sets the low signal level forCh1Wfm1 to 1.5 mV. C1W1 corre-
sponds to suffix number 2.
Usage: Asynchronous command
REFLevel<m>:ABSolute:TDIStance <Value>
The distance between the high signal level and the upper reference level.
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 118, 151 to 157,
173 to 179
Source waveform of the measurement, see Chapter 22.4.1,
"Waveform suffix", on page 1141.
Parameters:
<Value>
Example:
REFLevel2:ABSolute:TDIStance 0.0002
Sets the top distance for Ch1Wfm1 to 0.2 mV. C1W1 corre-
sponds to suffix number 2.
Example: See: "Manual reference level definition using absolute values"
on page 1129
Usage: Asynchronous command
Automatic measurements