EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1560

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1560User Manual 1337.9952.02 ─ 12
Parameters:
<UseAddress> ON | OFF
*RST: OFF
TRIGger<m>:I2C:ADOR<n>:ADRType <AddressType>
Sets the address type for the indicated ADOR address in the "address OR" trigger con-
dition.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<AddressType> BIT7 | BIT7_RW | BIT10
*RST: BIT7
TRIGger<m>:I2C:ADOR<n>[:VALue]
<Address>
Defines the address pattern of the indicated ADOR address in the "address OR" trigger
condition.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<Address> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148.
TRIGger<m>:I2C:ADOR<n>:RWBit <RWBit>
Defines the R/W bit of the indicated ADOR address in the "address OR" trigger condi-
tion.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<RWBit> UNDefined | READ | WRITe | EITHer
UNDefined
Return value only
*RST: EITHer
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Related product manuals