Remote control commands
R&S
®
RTP
1642User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:CAN:DLC <SearchName>,<WordCount>
SEARch:TRIGger:CAN:DLC? <SearchName>
Sets the Data Length Code, the number of data bytes to be found. For complete defini-
tion, set also the operator with SEARch:TRIGger:CAN:DLCCondition.
Parameters:
<WordCount> Range: 1 to 8
Increment: 1
*RST: 1
Parameters for setting and query:
<SearchName>
SEARch:RESult:CAN:FRAMe<m>:NDBYtes? <SearchName>
Returns the number of data bytes defined by DLC. DLC and NDB are different in CAN
FD for DLCs > 8.
See also: "Data setup: DLC, NDB, Transfer, Condition, Data min, Data max"
on page 568.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<NDBytes> Range: 1 to 64
Increment: 1
*RST: 1
Usage: Query only
SEARch:TRIGger:CAN:FDATa:DPOPerator <SearchName>,<DataPosOperator>
SEARch:TRIGger:CAN:FDATa:DPOPerator? <SearchName>
Sets the operator for the data position if DLC ≥ 9. You can define an exact position, or
a position range.
The setting is available in CAN FD option R&S RTP-K9.
Parameters:
<DataPosOperator> ANY | OFF | EQUal | GETHan | INRange | RANGe
ANY = OFF
The data position is not relevant for the search.
EQUal | GETHan
Equal, Greater or equal than. These conditions require one data
position to be set with SEARch:TRIGger:CAN:FDATa:
DPOSition.