EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1642

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1642User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:CAN:DLC <SearchName>,<WordCount>
SEARch:TRIGger:CAN:DLC? <SearchName>
Sets the Data Length Code, the number of data bytes to be found. For complete defini-
tion, set also the operator with SEARch:TRIGger:CAN:DLCCondition.
Parameters:
<WordCount> Range: 1 to 8
Increment: 1
*RST: 1
Parameters for setting and query:
<SearchName>
SEARch:RESult:CAN:FRAMe<m>:NDBYtes? <SearchName>
Returns the number of data bytes defined by DLC. DLC and NDB are different in CAN
FD for DLCs > 8.
See also: "Data setup: DLC, NDB, Transfer, Condition, Data min, Data max"
on page 568.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<NDBytes> Range: 1 to 64
Increment: 1
*RST: 1
Usage: Query only
SEARch:TRIGger:CAN:FDATa:DPOPerator <SearchName>,<DataPosOperator>
SEARch:TRIGger:CAN:FDATa:DPOPerator? <SearchName>
Sets the operator for the data position if DLC 9. You can define an exact position, or
a position range.
The setting is available in CAN FD option R&S RTP-K9.
Parameters:
<DataPosOperator> ANY | OFF | EQUal | GETHan | INRange | RANGe
ANY = OFF
The data position is not relevant for the search.
EQUal | GETHan
Equal, Greater or equal than. These conditions require one data
position to be set with SEARch:TRIGger:CAN:FDATa:
DPOSition.
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTP Series

Related product manuals