Remote control commands
R&S
®
RTP
1738User Manual 1337.9952.02 ─ 12
Return values:
<SrcAddress> String parameter
Usage: Query only
BUS<m>:ETHernet:WORD<n>:TYPE?
The sub-protocol (e.g. HTML, video, etc.) determines what meaning this field has.
Since the content of this data area is not decoded, the interpretation of the TYPE field
is ambivalent.
Suffix:
<m>
.
1..4
<n> *
Return values:
<Type> Returns the word type (specific for the sub-protocol), or the
length of the selected word.
Range: 0 to 65535
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:ETHernet:WORD<n>:DATA?
Returns the number of word bytes in brackets [.] followed by the first six word bytes of
data in hexadecimal format.
Use BUS<m>:ETHernet:WORD<n>:BYTE<o>:VALue? to access the word bytes.
Suffix:
<m>
.
1..4
<n> *
Return values:
<Data> String parameter
Example:
BUS:ETHernet:WORD3:DATA?
<-- '[60]FF00FFFF1234'
Usage: Query only
BUS<m>:ETHernet:WORD<n>:CRC?
Returns the Cyclic Redundancy Code (CRC, or frame check) checksum of the selected
word.
Suffix:
<m>
.
1..4
<n> *