Remote control commands
R&S
®
RTP
1802User Manual 1337.9952.02 ─ 12
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:TBTO:DATA:IMIN <SearchName>,<DataIndexMin>
SEARch:TRIGger:TBTO:DATA:IMIN? <SearchName>
Specifies the index bit pattern, or sets the start value of a pattern range.
Parameters:
<DataIndexMin> Range: 1 to 0
Increment: 1
*RST: 1
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:TBTO:ERRor:CRC <SearchName>,<ErrorCRC>
SEARch:TRIGger:TBTO:ERRor:CRC? <SearchName>
Enables search for cyclic redundancy check (CRC) error.
Parameters:
<ErrorCRC> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:TBTO:ERRor:FEC <SearchName>,<ErrorFEC>
SEARch:TRIGger:TBTO:ERRor:FEC? <SearchName>
Enables search for RS-FEC errors.
Parameters:
<ErrorFEC> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:TBTO:ERRor:OOR <SearchName>,<ErrorOOR>
SEARch:TRIGger:TBTO:ERRor:OOR? <SearchName>
Enables search for values that are out of range.
Parameters:
<ErrorOOR> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
Protocols