Remote control commands
R&S
®
RTP
1910User Manual 1337.9952.02 ─ 12
SEARch:TRIGger:MPHY:CRC:MAX <SearchName>,<CRCMax>
SEARch:TRIGger:MPHY:CRC:MAX? <SearchName>
Sets the end value of the CRC range if SEARch:TRIGger:MPHY:CRC:CONDition is
set to INRange or OORange.
Parameters:
<CRCMax> Numeric or string pattern, see Chapter 22.4.6, "Bit pattern
parameter", on page 1148. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:CREQ <SearchName>,<REQ>
SEARch:TRIGger:MPHY:CREQ? <SearchName>
Specifies the CREQ bit pattern.
Parameters:
<REQ> ONE | ZERO | DC
ONE
Sets the trigger condition to binary 1.
ZERO
Sets the trigger condition to binary 0.
DC
Sets the trigger condition to any CREQ value (don't care).
*RST: DC
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:RREQ <SearchName>,<REQ>
SEARch:TRIGger:MPHY:RREQ? <SearchName>
Specifies the RREQ bit pattern.
Parameters:
<REQ> ONE | ZERO | DC
ONE
Sets the trigger condition to binary 1.
ZERO
Sets the trigger condition to binary 0.
DC
Sets the trigger condition to any RREQ value (don't care).
*RST: DC
Parameters for setting and query:
<SearchName>
Protocols