Remote control commands
R&S
®
RTP
2075User Manual 1337.9952.02 ─ 12
Suffix:
<m>
.
*
Specifies the field number within the frame.
<n> *
Parameters:
<DataMax> Specifies the name of the generic trigger setting frame, see
SEARch:RESult:USBThree:FRAMe<m>:TYPE?
on page 2077.
Parameters for setting and query:
<SearchName> String with the name of the search.
SEARch:TRIGger:USBThree:BIT
<SearchName>,<Frame>, <Field>, <Bit>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:BIT <SearchName>,<BitState>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:BIT? <SearchName>
Sets the bit state of a field to be searched that only consists of one bit.
Suffix:
<m>
.
*
Specifies the frame.
<n> *
Specifies the field number within the frame.
Parameters:
<BitState> ONE | ZERO | DC
ONE
1
ZERO
0
DC
"Don't care" (DC) = X
*RST: DC
Parameters for setting and query:
<SearchName> String with the name of the search.
SEARch:TRIGger:USBThree:IOPerator <SearchName>,<Frame>, <Field>,
<Operator>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:IOPerator
<SearchName>,<IndexOperator>
SEARch:TRIGger:USBThree:FRAMe<m>:FLD<n>:IOPerator? <SearchName>
Sets the operator for the index for searching in the selected field of the selected frame.