Remote control commands
R&S
®
RTP
2113User Manual 1337.9952.02 ─ 12
Return values:
<Data> 8-bit data value
Example:
BUS:SWIRe:RESults:FRAMe2:DATA?
<-- #H12
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:STARt?
Returns the start time of the specified frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<Start> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
BUS<m>:SWIRe:RESults:FRAMe<n>:STATe?
Returns the overall state of the frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the serial bus.
Return values:
<State> OK | PAR | ESC | AMB | INComplete
OK
The frame is valid.
PARity
Parity error
ESC
Escape error
AMB
Ambiguous
INComplete
The frame is incomplete
*RST:
OK