EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 557

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTP
557User Manual 1337.9952.02 ─ 12
Figure 13-7: Configuration for CAN
See also: Chapter 13.1.1, "Setup - general settings", on page 512
Protocol
Defines the protocol type of the selected serial bus.
Remote command:
BUS<m>:TYPE on page 1548
Decode
Enables the decoding of the selected bus. The signal icon of the bus appears on the
signal bar.
Remote command:
BUS<m>[:STATe] on page 1548
Data
Sets the source of the selected data line.
Usually, the source is one of the analog channels. Reference and math waveforms are
available as source if the trigger source is one of the analog channels but not the serial
bus.
Alternatively, digital channels can be used if MSO option R&S RTP-B1 is installed. Dig-
ital and analog channels cannot be used at the same time.
For triggering on a serial bus, analog or digital channel sources are required.
CAN and CAN FD (option R&S