Protocol analysis
R&S
®
RTP
919User Manual 1337.9952.02 ─ 12
"Bit rate"
Nominal frequency or bit rate of the data signal.
"Range UI"
Number of unit intervals that are visible in the eye diagram.
"Position UI"
Place of the zero point in the diagram, in unit intervals. The zero point
is the alignment point on which the segment timestamps are superim-
posed.
Remote command:
EYE<m>:HORizontal:UINTerval:BITRate on page 2187
EYE<m>:HORizontal:UINTerval:RANGe on page 2187
EYE<m>:HORizontal:UINTerval:POSition on page 2187
Display settings
Access: [App Cockpit]> "Analysis" > "DDR Eye" > "Display" tab
In the "Display" tab, you define the appearance of the individual eye diagrams.
You can configure and analyze up to four independent eye diagrams in parallel (vertical
subtabs E1 to E4). Make sure to select the correct eye diagram subtab on the left
before you adjust the settings.
Color table assignment
Like any other waveform, you can show the eye waveform in solid color, or apply a
color table. If you select solid color, the intensity of the waveform is proportional to the
number Z of waveform slice points that hit a point (X,Y).
Chapter 4.3.2, "Color tables", on page 98.
DDR (option R&S
RTP-K91/K93 )

Table of Contents