RTC6 boards
Doc. Rev. 1.0.21 en-US
10 RTC6 Commands
391
innovators for industry
Normal List
Command
fly_return_z
Function Deactivates the previously set Processing-on-the-fly correction. Subsequently executes a
jump to the defined position.
Restriction If the Option Processing-on-the-fly is not enabled, fly_return_z only executes the jump to
the defined new output position.
Call
fly_return_z( X, Y, Z )
Parameters
X
Absolute x coordinate of the new output position. In bits.
As a signed 32-bit value.
Allowed value range: [–524,288…+524,287].
Out-of-range values are clipped to the boundary values.
Y
Like
X
(analogously).
Z
Like
X
(analogously).
Comments Like fly_return, however, with additional
Z
output position.
RTC4RTC6 New command.
In RTC4 Compatibility Mode, the RTC6 multiplies the specified value for
X
,
Y
and
Z
by 16.
The allowed value range decreases accordingly.
RTC5RTC6 Unchanged functionality.
In RTC5 Compatibility Mode, the RTC6 multiplies the specified value for
Z
by 16.
The allowed value range decreases accordingly.
Version info Available as of DLL 600, OUT 600, RBF 600.
References set_fly_z