10 RTC6 Commands
517
innovators for industry
Comments
(cont’d)
load_varpolydelay is not executed (get_last_error return code
RTC6_BUSY
), if:
the BUSY list execution status is set (a list is being processed or has been halted by
pause_list)
the INTERNAL-BUSY list execution status is set
load_varpolydelay is even executed, if:
a list has been paused by set_wait (PAUSED list execution status set)
During the runtime of load_varpolydelay, External Starts are suppressed.
Before loading a table, load_varpolydelay performs a DSP memory check that
produces error code 4 in case of error.
The table can be saved by create_dat_file.
RTC4RTC6 Basically unchanged functionality. However:
To return to the internal standard Mark Delay table, a reset or renewed program
loading by load_program_file is no longer necessary (see
Name
= NULL above).
The ASCII text file can have any filename extension.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References load_program_file, set_delay_mode, create_dat_file
Ctrl Command load_varpolydelay