10 RTC6 Commands
846
Comments
(cont’d)
• The active Processing-on-the-fly mode determines whether the galvanometer scanners
remain stationary during the wait or move in accordance with encoder changes, see
Chapter 8.6.7 ”Synchronizing Processing-on-the-fly Applications”, page 252: They
move with set_fly_2d, but otherwise remain stationary.
• Mode = 0 or
±1 waits for direct encoder values: “classic” behavior.
• Mode =
±2 waits for encoder values that are expected to be present in
(set_scanahead_params parameter)
PreviewTime
: SCANahead System behavior.
RTC4RTC6 New command.
RTC5RTC6 Unchanged functionality.
Version info Available as of DLL 600, OUT 600, RBF 600.
References get_encoder, store_encoder, read_encoder, simulate_encoder, wait_for_encoder,
wait_for_encoder_in_range, park_position, park_return
Normal List
Command
wait_for_encoder_mode