RM0008 Advanced-control timers (TIM1&TIM8)
207/690
Interrupt/DMA generation on the following events:
Update: counter overflow/underflow, counter initialization (by software or
internal/external trigger)
Trigger event (counter start, stop, initialization or count by internal/external trigger)
Input capture
Output compare
–Break input
Supports incremental (quadrature) encoder and hall-sensor cicuitry for positioning
purposes
Trigger intput for external clock or cycle-by-cycle current management