EasyManuals Logo

ST STM32F102 series User Manual

ST STM32F102 series
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #511 background imageLoading...
Page #511 background image
RM0008 Controller area network (bxCAN)
511/690
Figure 200. Example of filter numbering
Filter priority rules
Depending on the filter combination it may occur that an identifier passes successfully
through several filters. In this case the filter match value stored in the receive mailbox is
chosen according to the following priority rules:
A 32-bit filter takes priority over a 16-bit filter.
For filters of equal scale, priority is given to the Identifier List mode over the Identifier
Mask mode
For filters of equal scale and mode, priority is given by the filter number (the lower the
number, the higher the priority).
9
8
ID List (32-bit)
ID Mask (32-bit)
ID List (16-bit)
ID List (32-bit)
Deactivated
ID Mask (16-bit)
ID List (32-bit)
Filter
0
1
3
5
6
9
ID Mask (32-bit)
13
FIFO0
Filter
0
1
2
3
4
5
6
7
10
11
12
13
ID Mask (16-bit)
ID List (32-bit)
ID Mask (16-bit)
ID List (16-bit)
Deactivated
ID Mask (16-bit)
ID List (32-bit)
Filter
2
4
7
8
10
11
ID Mask (32-bit)
12
FIFO1
Filter
0
1
2
4
5
6
7
8
11
12
13
14
3
Deactivated
9
10
Num. Num.BankBank
ID=Identifier

Table of Contents