EasyManuals Logo

ST STM32F102 series User Manual

ST STM32F102 series
690 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #337 background imageLoading...
Page #337 background image
RM0008 Basic timer (TIM6&7)
337/690
Bit 2 URS: Update Request Source.
This bit is set and cleared by software to select the UEV event sources.
0: Any of the following events generates an update interrupt or DMA request if enabled. These
events can be:
– Counter overflow/underflow
– Setting the UG bit
– Update generation through the slave mode controller
1: Only counter overflow/underflow generates an update interrupt or DMA request if enabled.
Bit 1 UDIS: Update Disable.
This bit is set and cleared by software to enable/disable UEV event generation.
0: UEV enabled. The Update (UEV) event is generated by one of the following events:
– Counter overflow/underflow
– Setting the UG bit
– Update generation through the slave mode controller
Buffered registers are then loaded with their preload values.
1: UEV disabled. The Update event is not generated, shadow registers keep their value (ARR,
PSC). However the counter and the prescaler are reinitialized if the UG bit is set or if a hardware
reset is received from the slave mode controller.
Bit 0 CEN: Counter enable.
0: Counter disabled
1: Counter enabled
Note: Gated mode can work only if the CEN bit has been previously set by software. However trigger
mode can set the CEN bit automatically by hardware.
CEN is cleared automatically in one-pulse mode, when an update event occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ST STM32F102 series and is the answer not in the manual?

ST STM32F102 series Specifications

General IconGeneral
BrandST
ModelSTM32F102 series
CategoryMicrocontrollers
LanguageEnglish

Related product manuals