2
nd
Edition - Rev 0
Page 14
05-20
INSPECTION PROGRAM
ATA
Item
Maintenance task
FREQUENCY
A
B
C
D
E
57
Wings
Inspect flap actuation mechanism and
electrical connections. Check for
condition, full travel and correct op-
eration. Check related indicator for
operation.
X
57
Wings
Disconnect wings from fuselage,
raise them enough to allow for check-
ing condition of attachments and for
likely play
X
57
Wings
Inspect control surfaces electrical
bonding connection for general con-
dition.
X
61
Propeller
Propeller: remove spinner and inspect
attaching bolts for proper lockwire.
X
61
Propeller
Check the propeller for surface dam-
age (skin cracks, distortion, dents).
Check the bolts torque values.
X
71
Power Plant
Engine mounts isolators: check for
integrity.
X
71
Power Plant
Check integrity of engine firewall.
Check for cracks, distortion or wrin-
kles.
X
71
Power Plant
Visually inspect engine mount struc-
ture for bent, cracked or buckled
tubes and engine mount isolators at-
tachments. Check engine mount bolts
and engine electrical bonding.
X
71
Power Plant
Engine electrical harness and equip-
ment: check for condition and securi-
ty of installation.
X
71
Power Plant
Check carburetors fuel drainage lines.
Check air box drainage lines.
X
71
Power Plant
Visually inspect air induction system
for integrity. Clean filter if required.
X