January 2012 4.10 List of Machine Parameters 559
speedTolerance
401103
Rotational speed (feed rate) window
Control window for message RPM ATTAINED.
Format: Numerical value
Input: 0.000 000 01 to 100 [%]
Default: 10 [%]
Allowed in
strobe
LEVEL 3
1024
timeSpeedOK
401104
Hysteresis time for monitoring the speed
deviation
Format: Numerical value
Input: 0.006 to 10 [s]
Default: 0.010 [s]
Allowed in
strobe
LEVEL 3
1024
syncTolerance
401105
Angle tolerance for spindle synchronism
Parameter reserved for lathe controls.
Format: Numerical value
Input: 0.001 000 000 to 2 [°]
Default: 0.01 [mm]
Allowed in
strobe
LEVEL 3
–
timeSyncOK
401106
Hysteresis time for spindle synchronism
Parameter reserved for lathe controls.
Format: Numerical value
Input: 0.000 000 000 to 20 [s]
Default: 0.010 [s]
Allowed in
strobe
LEVEL 3
–
CfgPowerStage
Settings for the power module of the axis
ampName
401201
MP2100.x
Type of axis/spindle power module
Format: Selection menu
Input: Name of the power module from
the inverter.inv power module table
(is entered by the MANUALplus
620)
RUN
LEVEL3
1074
ampPowerSupplyType
401202
MP2191
(optional parameter)
Power module with or without energy
recovery
Define the parameter only if no power module
table is defined through CfgSupplyModule and
MP_motSupply for the axis/spindle.
Format: Selection menu
Input:
without power recovery:
Power module without energy recovery
with power recovery:
Power module with energy recovery
Default: without power recovery
RUN
LEVEL3
1085
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page