570 HEIDENHAIN Technical Manual MANUALplus 620
motEncSerialNumber
401317
MP2257.x
(optional parameter)
Control or encoder identification for the field
angle from MP_motPhiRef
Format: Numerical value
Input: Is entered by the MANUALplus 620
0: Field angle not yet determined
Default: 0
RUN
LEVEL3
1070
motAdditionalInfo
401318
(optional parameter)
Reserved, do not assign
Format: Numerical value
Input: Reserved
Default: 0
RUN
LEVEL3
1075
motSpeedSwitchOver
401319
MP2186.x
(optional parameter)
Shaft speed for PWM switchover
Only for the CC 61xx/UEC 11x and CC 424.
Specifies the shaft speed at which the PWM
frequency is switched to twice the PWM
frequency. Use only in combination with
HEIDENHAIN power modules!
Format: Numerical value
Input: 0 to 100 000 [rpm]
Default: 0
RUN
LEVEL3
597 110-03
940
motSpeedSwitchBack
401320
MP2188.x
(optional parameter)
Shaft speed for PWM switchover
Only for the CC 61xx/UEC 11x and CC 424.
Specifies the shaft speed at which the factor 2
PWM frequency is switched to a factor 1. Use
only in combination with HEIDENHAIN power
modules!
Format: Numerical value
Input: 0 to 100 000 [rpm]
Default: 0
RUN
LEVEL3
940
testBrakeCurrent
401323
MP2230.x
(optional parameter)
Test of motor brake: Factor for motor stall
current
Format: Numerical value
Input: 0.1 to 30 [· motor stall current]
Recommended: 1.3 · M
L
/ M
0
RUN
LEVEL3
597 110-05
987
testBrakeTolerance
401324
MP2232.x
(optional parameter)
Test of motor brake: Maximum permissible
path
Format: Numerical value
Input: 0 to 10 [mm] or [°]
RUN
LEVEL3
987
Parameter
MP number
iTNC MP number