EasyManua.ls Logo

HEIDENHAIN MANUALPLUS 620 - Page 570

HEIDENHAIN MANUALPLUS 620
1818 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
570 HEIDENHAIN Technical Manual MANUALplus 620
motEncSerialNumber
401317
MP2257.x
(optional parameter)
Control or encoder identification for the field
angle from MP_motPhiRef
Format: Numerical value
Input: Is entered by the MANUALplus 620
0: Field angle not yet determined
Default: 0
RUN
LEVEL3
1070
motAdditionalInfo
401318
(optional parameter)
Reserved, do not assign
Format: Numerical value
Input: Reserved
Default: 0
RUN
LEVEL3
1075
motSpeedSwitchOver
401319
MP2186.x
(optional parameter)
Shaft speed for PWM switchover
Only for the CC 61xx/UEC 11x and CC 424.
Specifies the shaft speed at which the PWM
frequency is switched to twice the PWM
frequency. Use only in combination with
HEIDENHAIN power modules!
Format: Numerical value
Input: 0 to 100 000 [rpm]
Default: 0
RUN
LEVEL3
597 110-03
940
motSpeedSwitchBack
401320
MP2188.x
(optional parameter)
Shaft speed for PWM switchover
Only for the CC 61xx/UEC 11x and CC 424.
Specifies the shaft speed at which the factor 2
PWM frequency is switched to a factor 1. Use
only in combination with HEIDENHAIN power
modules!
Format: Numerical value
Input: 0 to 100 000 [rpm]
Default: 0
RUN
LEVEL3
940
testBrakeCurrent
401323
MP2230.x
(optional parameter)
Test of motor brake: Factor for motor stall
current
Format: Numerical value
Input: 0.1 to 30 [· motor stall current]
Recommended: 1.3 · M
L
/ M
0
RUN
LEVEL3
597 110-05
987
testBrakeTolerance
401324
MP2232.x
(optional parameter)
Test of motor brake: Maximum permissible
path
Format: Numerical value
Input: 0 to 10 [mm] or [°]
RUN
LEVEL3
987
Parameter
MP number
iTNC MP number
Function and input Reaction/
Access
Page