610 HEIDENHAIN Technical Manual MANUALplus 620
Axis – Control
M NN_AxReferenceAvailable
(W1032)
Reference mark not yet traversed 597 110-01 804
M PP_AxReferenceEndPosition
(W1054)
Reference end position 597 110-01 804
D PP_AxManualFeedMax Maximum axis feed rate in all operating
modes [mm/rev]
597 110-01 847
M PP_AxFeedEnable
(W1060)
Axis-specific feed-rate enable 597 110-01 852
M NN_AxMotionRequest Axis movement by the interpolator 597 110-01 957
M NN_AxInMotion
(W1028)
Axes in motion 597 110-01 958
M NN_AxInPosition
(W1026)
Axes in position 597 110-01 957
M NN_AxStopExtern Axis motion is stopped and canceled by run-
time system (e.g. upon demand by
functional safety FS)
597 110-05
M PP_AxTraversePos
(W1046)
Manual traverse in positive direction 597 110-01 847
M PP_AxTraverseNeg
(W1048)
Manual traverse in negative direction 597 110-01 847
M PP_AxHandwheelLocked
(W1062)
Disable handwheel motion for specific axes 597 110-01 1338
M PP_AxDeactivateMonitoring
(W1042)
Deactivate monitoring functions 597 110-01 947
M NN_AxLubricationPulse
(W1056)
Lubrication pulse: Value in
MP_lubricationDist exceeded. Remains set
until the path is reset by
PP_AxLubricationDistReset.
597 110-01 690
M PP_AxLubricationDistReset
(W1058)
Reset the accumulated distance 597 110-01 690
Operand Description SW