Keysight M8000 Series of BER Test Solutions User Guide 449
Setting up Patterns 7
Link Training USB 3.0 and USB 3.1 Parameters
The following table shows the parameters which can be configured for link
training USB 3.0 and USB 3.1:
Parameter name Values Default Description Applicable
for USB
LTSSM
3.0 / 3.1
DUT Type
XML: usbDut
Host
Device
Device Specifies which role the BERT
should play during link training. It
can be either an downstream port
(Host) or an upstream port (Device)
Both
Target State
XML: targetState
LoopbackViaPolling LoopbackVia
Polling
Determines the target state when
bringing up the link
Both